Europe Embedded AC EV Charger for Smart Lamp Posts
General product data
| Version | Embedded AC EV charger for smart lamp poles; OCPP-enabled; nominal 22 kW@ 3-phase 400 V, with reduced output when operated on 1-phase 230 V. |
|---|---|
| Product family | Smart Lamp Post Charger(OCPP) |
| Model | TDT-A3-3P-EV032 |
| Manufacturer | Shenzhen TDT Co., Ltd. |
| Nominal electrical architecture | 3-phase, 400 V AC, 32 A |
| Integrated communications | Wi-Fi, Bluetooth 5.0, Ethernet, RFID; optional 4G/LTE; OCPP 1.6J |
Product overview
| Application | AC charging for electric vehicles with on-board chargers. |
|---|---|
| Applicable scenario | Installation on smart street lamp poles and courtyard lamp poles |
| Integration concept | Embedded directly in the smart lamp pole/ compatible with lamp pole structure |
| Display | 4.3 inch screen. |
Performance specification
| Input voltage | AC 400 V ±10%/ AC 230 V ±10% |
|---|---|
| Input Frequency | 50/60 Hz |
| Rated operating current | 32 A |
| Rated output current | 32A |
| Maximum output power | 22 kW on 3-phase input; setup notes indicate approx. 7.36 kW when the same unit is operated from single-phase input. |
| Standby power | < 6 W |
| Source compatibility | Grid / Solar / Energy Storage systems. |
| Operation mode | Plug and Play / RFID / OCPP Protocol, Compatible with Third-party APP& Platform |
Environmental and mechanical data
| Operating temperature | -30 °C to+50 °C |
|---|---|
| Storage temperature | -30 °C to +70 °C |
| Operating humidity | 5% to 95% RH, non-condensing |
| Working altitude | < 2000 m |
| Protection degree | IP54 |
| MTBF | 50,000 hours |
| Wiring mode | Bottom cable entry; Bottom / Front cable exit |
| External dimensions | L×W×D: 455 × 140 × 142 mm(long shell) L×W×D: 400 × 142 × 100 mm(standard shell) Overall dimensions with tolerance: ±2.5 mm |
Safety and standards
| Protection functions | Overvoltage, Undervoltage, Overcurrent, Short-circuit, Leakage, Grounding Protection, Over-temperature& Low-temperature Protection. Lightning protection shall be installed separately by the user. |
|---|---|
| Leakage protection | Type A+ 6 mA DC sensitive RCCB(IEC 62955 compliant). |
| Charging/ connector standards | EN IEC 61851; EN 62196 Type 2. |
| Radio/ RED-related standardslisted in DoC | EN 301 489-1, EN 301 489-17, EN 300 330, EN 300 328, EN IEC 62311, EN 301 489-3;4G/ LTE: EN 301 908-1, EN 301 908-13, EN 301 489-52, EN 62368-1. |
Interfaces and communication
| Wi-Fi | 2.412 to 2.483 GHz, IEEE 802.11 b/g/n. |
|---|---|
| Bluetooth | Bluetooth 5.0, 2.402 to 2.480 GHz. |
| 4G/ LTE | Optional. LTE-FDD: B1 / B3 / B7 / B8 / B20 / B28; GSM: GSM 900/ DCS 1800 |
| RFID | 13.56 MHz, compliant with EN 300 330 |
| Ethernet | RJ-45 connection; external crystal reference frequency 25 MHz and SPI interface communication frequency 33.3 MHz to 80 MHz. |
| Communication protocol | OCPP 1.6J. |
| Networking note | Ethernet and WiFi connect to the local network; all models support cloud. transmission, while cellular uploads directly via mobile network.. |
| Vehicle-user control | Plug& Play, RFID, APP / platform control. |
Installation and connection notes
| Mounting concept | Embedded installation in a matching lamp pole. |
|---|---|
| Supply cable guidance | Manual recommends 1-phase 3 x 6 mm² and 3-phase 5 x 6 mm² or above, subject to construction length. |
| Communication cable guidance | Shielded network cable(Cat 5 / super class 5) for networking mode, subject to construction length. |
| Front-stage breaker note | We recommend the 40A breaker as the standard configuration. However, if you prefer a higher safety margin for long-term stability, the 63A option is also fully compatible and safe |
| Grounding | The equipment must be grounded during use. |
| Current-limiting note from setup correspondence | Unit was described as factory-set for 32 A. Physical DIP switch selects 32 A or 16 A; setup notes indicate 16 A limits power to approx. 11 kW on 3-phase or 3.68 kW on 1-phase. |
Illustrative visuals

| Product visual from manual |
|---|
| Type B connection drawing from manual(long curved shell) |
| Type B connection drawing from manual (long rectangle shell) |
| Type B connection drawing from manual (standard rectangle shell) |
Request a quotation
Tell us your target market, required voltage (e.g. 230 V / 400 V) and quantity — our engineers reply within one working day.
Email: sales@tdtevse.com | WhatsApp: +86 134 2131 0407
Related
Smart lamp post EV chargers · Smart Lamp Post AC EV Charger · America Embedded Smart Street Lamp Post AC EV Charger · Smart street lamp post AC EV charger solution · Pole-integrated EV charging: bringing chargers into street-light poles
Frequently asked questions
What does this product do?
Embedded AC EV charger for smart lamp poles in Europe (model TDT-A3-3P-EV032). It delivers up to 22 kW on a 3-phase 400 V supply (reduced output on 1-phase 230 V), supports OCPP 1.6J, and integrates directly into the lamp-pole structure.
Do you support OEM and custom housing?
Yes — we manufacture in-house, so housing, colour and branding can be adapted to your market. Tell us your target country and required voltage and we will recommend a configuration.
Is OCPP supported?
Our networked chargers support OCPP 1.6J, so they integrate with standard back-end platforms without vendor lock-in.
What certifications do you hold?
Our chargers are CE and RoHS compliant, with IP ratings suited to outdoor installation. Specific certification documents are available on request.
What is the minimum order quantity and lead time?
It depends on the model and the degree of customisation. Send us your requirement and we will confirm MOQ and lead time within one working day.
How do I get a quotation?
Email sales@tdtevse.com or WhatsApp +86 134 2131 0407 with your target market, required voltage and quantity — our engineers reply within one working day. You can also use our contact page.